Voyager 3000
SCSI RAID Storage Array
User’s Manual
MAN-VRA3000UG-1
Revision A4_1
10-November-1997
Przeglądanie stron 0
1 2 3 4 5 6 ... 73 74

Podsumowanie treści

Strona 1 - Voyager 3000

Voyager 3000SCSI RAID Storage ArrayUser’s ManualMAN-VRA3000UG-1Revision A4_110-November-1997

Strona 2 - Contents

xTHE EXPRESSED WARRANTIES SET FORTH IN THIS AGREEMENT ARE IN LIEU OFALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING WITHOUTLIMITATION, ANY WARRA

Strona 3

Chapter One IntroductionVoyager 3000 FamilyThe Voyager 3000 is a cost effective open architecture RAID solution. All Voyager 3000systems include 8MB

Strona 4

Voyager 3000 User Guide1-2Table 1-4 Host Connection CodesFW Fast Wide single endedFWD Fast wide differentialUW Ultra SCSI wideUD Ultra SCSI wide diffe

Strona 5

Introduction1-3VRA-3002T-XX-YThis is a twin tower RAID configuration made up of a single controller and 13 drives asshown in Figure 1-3.Figure 1-2 Int

Strona 6

Voyager 3000 User Guide1-4This system will typically be used in similar situations to that described within the VRA-3001T-XX-Y section on page 1-2 but

Strona 7

Introduction1-5VRA-3001R-XX-YThis system will be used in a rackmount configuration and will normally be part of anexpandable system. Customers can add

Strona 8 - Disclaimer

Voyager 3000 User Guide1-6VRA-3002R-XX-YThis system is similar to the VRA-3002T-XX-Y and is used for expandable storage. Eachshelf has a measurement

Strona 9 - Warranty

Introduction1-7OptionsRCM-RC1-CD Vision Software - Availability to be announcedVSA-401TE-Y Single tower expansion kit for VRA-3001T - 1 shelf, 7stora

Strona 10

Voyager 3000 User Guide1-8• Comprehensive failure management including:Automatic bad sector reassignmentHot-swappingGlobal and Local Spare drive opera

Strona 11 - Chapter One

Introduction1-9The industry standard SCA2 connector is used to interface between the device and thebackplane. SCA features staggered contact pins and

Strona 12 - VRA-3001T-XX-Y

iiContentsChapter One...1-1Int

Strona 13 - VRA-3002T-XX-Y

Voyager 3000 User Guide1-10RAID 3Block Striping with Dedicated Parity - Data is broken into logical blocks, the size of a SCSIdisk block, and striped

Strona 14

Chapter Two Installation and SetupUnpacking and Initial SetupOn receipt of the system visually inspect the exterior of the packaging for any signs of

Strona 15 - VRA-3001R-XX-Y

Voyager 3000 User Guide2-2Electrical ConsiderationsCircuit OverloadingCare should be taken to ensure that the current does not exceed the rating of th

Strona 16 - VRA-3002R-XX-Y

Installation and Setup2-3A ground point for securing the braid is provided at the rear of the rack and is shown in Figure2-2.Setting the host SCSI Ids

Strona 17 - • Five operating modes:

Voyager 3000 User Guide2-42. Refer to Figure 2-4 and remove the ACMs by unscrewing the large single screw, swingingback and unclipping the snap on wi

Strona 18 - Power Supplies

Installation and Setup2-5The switches are now accessible at the middle of the backplane on the right hand side whenlooking at the rear of the system

Strona 19 - RAID Basics

Voyager 3000 User Guide2-6Switch positions 1-4 are used to set the starting ID for the first device (bay 0) on the bus.Devices in bays 1,2 and 3 will

Strona 20

Installation and Setup2-7SW-1 of DPS1 corresponds to the L.S.B. of the ID of the device in bay 0, whilst SW- 4corresponds to the MSB of the ID of the

Strona 21 - Chapter Two

Voyager 3000 User Guide2-8Table 2-1 SCSI ID switch settings for the second backplane in a VRA-3002 configuration.DPS1 Sw1(ID Bit0)DPS1 Sw2(ID Bit1)DPS

Strona 22 - Grounding

Installation and Setup2-9Note Ultra SCSI has very stringent requirements regarding cable length.Any cables connected to Ultra devices must conform to

Strona 23 - Setting the target SCSI Ids

iiiEMU Features ...3-1System Configurations...

Strona 24

Voyager 3000 User Guide2-10SCA attachmentTo connect an SCA device to a device carrier simply insert the SCA device and connect it viathe 4 screw holes

Strona 25

Installation and Setup2-11Access to the controller is obtained by removing the four screws at the side of the top panel.This will allow access to the

Strona 26

Voyager 3000 User Guide2-12• Use 72-pin 60 Ns DRAM or EDO SIMM.• Maximum DRAM size is 32 MBytes in one 32 MByte SIMM.Installation of SIMMs is accompli

Strona 27

Installation and Setup2-13Refer to Figure 2-15 and remove the ACMs by unscrewing the large single screw, swingingback and unclipping the snap-on wirin

Strona 28

Voyager 3000 User Guide2-14PSU Insertion and RemovalThe VOYAGER 3000’s power supply is designed for hot pluggable operation. To achieve thistemperatur

Strona 29 - Components

Environmental Monitoring Unit3-1Chapter Three EMUEnvironmental Monitoring Unit ConfigurationsIntroductionThe Environmental Monitoring Unit ( EMU ) is

Strona 30 - and will

Voyager 3000 User Guide3-2System ConfigurationsSingle Shelf configurationFigure 3-1 shows how a single shelf Voyager 3000 system is configured with an

Strona 31 - SIMM Installation

Environmental Monitoring Unit3-3Setting up the EMUThe EMU is physically located at the rear of the device shelf. A magnified view of the EMU isshown i

Strona 32 - Advanced Cooling Modules

Voyager 3000 User Guide3-4Switch Signal Name Description Default SettingSW1 ID2 Address Bit 2 Setting isSW2 ID1 Address Bit 1 positionSW3 ID0 Address

Strona 33 - Drive Removal

Environmental Monitoring Unit3-5SW5 SW6 ActionOff Off No delayed power sequencingOn Off Power sequencing if only 1 PSU is availableX On Delayed power

Strona 34 - PSU Insertion and Removal

ivFiguresFigure 1-1 VRA-3001T-XX-Y Single Tower...1-2Figure 1-2 Internal bus con

Strona 35 - Chapter Three

Voyager 3000 User Guide3-6Each slave EMU will have the same data available to the Master and Host as is shown inTable 3-4 and Table 3-5. Table 3-6 sho

Strona 36 - System Configurations

Environmental Monitoring Unit3-7Connecting the EMUThis section describes the procedure for connecting the EMU to the host system. It is possibleto hav

Strona 37 - Setting up the EMU

Voyager 3000 User Guide3-8This page is intentionally left blank.

Strona 38 - SW1 SW2 SW3 EMU ID

Chapter Four RAID controller configurationController DescriptionThe VOYAGER 3000 is a SCSI to SCSI RAID controller specifically designed to provideRA

Strona 39 - Available EMU information

Voyager 3000 User Guide4-2Accessing the VOYAGER 3000 MenusConnecting a MonitorThe VOYAGER 3000 is shipped with a serial cable for making the connectio

Strona 40

RAID Controller Configuration4-3First conne

Strona 41 - Connecting the EMU

Voyager 3000 User Guide4-4The next step is to set up the terminal preferencesDe-select Use Function, Arrow and Ctrl Keys for Windows check box as sho

Strona 42 - Voyager 3000 User Guide

RAID Controller Configuration4-5and then c

Strona 43 - Chapter Four

Voyager 3000 User Guide4-6menus and press the v key to back up to previous levels. Entries are selected via the ekey.Creating a logical volumeA "

Strona 44 - Emulating a Monitor

RAID Controller Configuration4-7Select Term

Strona 45

vFigure 4-21 Selecting two drives to form a RAID 1 set ...4-11Figure 4-22 Viewing all Logical Dri

Strona 46

Voyager 3000 User Guide4-8matches the actual configuration. This is done by selecting view and edit SCSI drives from themain menu as shown in Figure 4

Strona 47

RAID Controller Configuration4-9Pressing th

Strona 48 - Creating a logical volume

Voyager 3000 User Guide4-10After the drives are selected we back up through the menus by pressing the v key. The nextdialogue to appear prompts the us

Strona 49

RAID Controller Configuration4-11Creating a

Strona 50

Voyager 3000 User Guide4-12The status of the SCSI drives are shown by selecting the View and Edit SCSI Drives optionfrom the Main Menu (Figure 4-11).

Strona 51

RAID Controller Configuration4-13Partitioni

Strona 52

Voyager 3000 User Guide4-14When all the available volume capacity has been divided up press the ESC key to exit.Mapping Host LUNsThe next stage is to

Strona 53

RAID Controller Configuration4-15We are now

Strona 54 - Adding a Global Spare

Voyager 3000 User Guide4-16De-assigning LUN MappingTo de-assign a LUN mapping scheme, enter the host LUN mapping screen and select thepartition to de-

Strona 55 - Partitioning a Logical Volume

RAID Controller Configuration4-17Select the

Strona 56 - Mapping Host LUNs

viTablesTable 1-1 Voyager 3000 Tower configurations...1-1Table 1-2 Voyager 3000 Rac

Strona 57

Voyager 3000 User Guide4-181. View Drive Information: this option gives information relating to the drive selected.Information about the drive Revisio

Strona 58 - Scan New SCSI Drives

RAID Controller Configuration4-194. Sync Tr

Strona 59 - View and Edit SCSI Drives

Voyager 3000 User Guide4-20View and Edit Configuration ParametersFrom the Main Menu select the View and Edit Configuration Parameters option. A screen

Strona 60 - View and Edit SCSI Channels

RAID Controller Configuration4-21View and E

Strona 61

Voyager 3000 User Guide4-22If an EMU is installed in the system it is necessary, before firmware download, to set theEMU in passive mode by holding do

Strona 62

Chapter Five Front Panel OperationThe VOYAGER 3000 includes default configurations that it proposes based on the numberand location of the drives ins

Strona 63 - Down Loading New Firmware

Voyager 3000 User Guide5-2 2 Press t or s to select View and Edit Logical Drives.and press ENT. View and Edit Logical Drives.. 3 Press t or s to selec

Strona 65 - Chapter Five

Voyager 3000 User Guide5-4Deleting a Logical Drive 1 Press ENT for two seconds for the Main Menu. 2 Press t or s to select View and Edit Logical Drive

Strona 66

Front Panel Oper

Strona 67 - Assigning a Spare Drive

viiScopeThis manual details the installation and configuration of Eurologic’s Voyager 3000 RAIDstorage arrays.

Strona 68 - Setting the SCSI Channels

Voyager 3000 User Guide5-6SCSI Reset at Power-Up Setting 1 Press ENT for two seconds for the Main Menu. 2 Press t or s to select Edit SCSI Reset at P

Strona 69

Front Panel Oper

Strona 70 - Viewing Connected Drives

Voyager 3000 User Guide5-8Have the host communication program "send" the file containing the data to be downloadedusing ZMODEM protocol. Whe

Strona 71 - Download Firmware

Appendix AVoyager 3000 SpecificationsRAID level 0, 1, 3, 5 (or non-RAID disk spanning)Failure management Bad sector reassignment, hotswapping, spare d

Strona 72

Voyager 3000 User GuideiiPower consumption Single tower 130 WattsTwin tower 260 WattsRack 130 WattsInternal host cable length 1 MetrePower Supply Rati

Strona 73 - Appendix A

viiiDisclaimerEUROLOGIC reserves the right to make changes to this manual and the equipment describedherein without notice. EUROLOGIC has made all rea

Strona 74

ixWarrantyBASIC WARRANTY—In the absence of any optional warranty or continuing provisions byformal agreement, EUROLOGIC warrants its products in accor